The 3 flap travel faults can only be recorded by the ECU when a fault code reading and clearing procedure has been carried out
At the beginning and end of fault code reading sequences, the ECU controls its reduction motors stop to stop
During fault code clearing, the ECU records the stop values of each of its reduction motors
Провести новое считывание кодов неисправности: if the stop values do not coincide with those stored in the memory, the ECU displays the fault code which corresponds to the flap, the next time that the fault codes are read
8065 - электродвигатель (/) заслонки смешивания воздушных потоков
8070 - моторедуктор впускной воздушной заслонки
8071 - моторедуктор распределительной заслонки
8080 - компьютер
If this kind of fault code appears, carry out the complete fault code reading/clearing procedure again, then read the fault codes again to confirm the fault code
Если неисправность исчезла, ничего не надо заменять
Если неисправность сохраняется: check that the flap moves freely
Если правильно: replace the reduction motor which corresponds to the fault code