Содержание Электросхемы Раздел: Отопление, вентиляция Все разделы

Мотор вентилятора - Неправильное функционирование Opel Signum I рестайлинг

Field Remedy: 2000

Subject:Blowermotor - Function not correct
Models:Engines:Option:
Vectra-C 2002...2006,Signum 2002...2006All,All
Complaint:Blower motor is running only in high speed, is without function or running when ignition is switched off.
Cause:Condensation water from blower motor accumulates at bottom of blower motor housing ( rust formation etc. ). Resistor is damaged.
Production:As of VIN W0L0ZCF3561069032 (13.01.2006) improved parts have been introduced in produktion.

Remedy:

In case of customer complaint check resistor and blower motor for water marks or rust. Drill a 4 mm hole at the lowest point of the blower motor housing (brush area) when the blower motor is removed.

FunctionalGroup:D - Heating/Ventilation/Air conditioning
Complaint Group:04 - Electrical failures
Trouble Code:None