Содержание Электросхемы Раздел: Графический информационный дисплей Все разделы

Graphic Info Display - Wrong range indication on GID after refilling the tank Opel Signum I рестайлинг

Field Remedy: 1756

Subject:Graphic Info Display - Wrong range indication on GID after refilling the tank
Models:Engines:Option:
Vectra-C 2002...2004,Signum 2003...2004All,All
Complaint:Wrong range indication on GID after refilling the tank.
Cause:Software bug in the display.
Production:As of the following breakpoints: Rüsselsheim, 18.03.2004, W0L0ZCF4841083201; Ellesmere Port, 22.03.2004, W0L0ZCF6848068051 modified parts have been introduced in produktion.

Remedy:

In case of customer complaint replace GID by a modified part.

Vehicles with radio CDR2005, CCR2006 and/or ECC: P/N 93182818, Cat.No. 62 36 494.

Vehicles with radio CCRT2008, NCDC2013/2015: P/N 93182819, Cat.No. 62 36 495.

FunctionalGroup:N - Electrical Equipment
Complaint Group:13 - No/Poor Function
Trouble Code:None