Field Remedy: 1756
| Subject: | Graphic Info Display - Wrong range indication on GID after refilling the tank |
|---|
| Models: | Engines: | Option: |
|---|---|---|
| Vectra-C 2002...2004,Signum 2003...2004 | All,All |
| Complaint: | Wrong range indication on GID after refilling the tank. |
|---|---|
| Cause: | Software bug in the display. |
| Production: | As of the following breakpoints: Rüsselsheim, 18.03.2004, W0L0ZCF4841083201; Ellesmere Port, 22.03.2004, W0L0ZCF6848068051 modified parts have been introduced in produktion. |
Remedy:
In case of customer complaint replace GID by a modified part.
Vehicles with radio CDR2005, CCR2006 and/or ECC: P/N 93182818, Cat.No. 62 36 494.
Vehicles with radio CCRT2008, NCDC2013/2015: P/N 93182819, Cat.No. 62 36 495.
| FunctionalGroup: | N - Electrical Equipment |
|---|---|
| Complaint Group: | 13 - No/Poor Function |
| Trouble Code: | None |