Field Remedy: 1613
| Subject: | Instruments - "InSP 0 km" is shown or programming of ECO Service - Fix is not possible,no communication with TECH 2 |
|---|
| Models: | Engines: | Option: |
|---|---|---|
| Meriva 2003,5 | All | None |
| Complaint: | IP-clusters of Meriva vehicles can not be diagnosed by the TECH 2 . |
|---|---|
| Cause: | No communication between IPC and TECH 2 |
| Production: | None |
Remedy:
In case of customer complaint, proceed as follows.
1. Remaining distance is not shown: IP - cluster is set to ECO Service - Fix. IP - cluster with "identifier" 12, 13, 16 and 17 can not be programmed to ECO Service - Fix.
2. Remaining distance "34000 km" for Gasoline engines / "50000 km" for Diesel engines is shown: A reset is not necessary. When less than these values reset should be carried out with TECH 2.
3."InSP 0 km" is shown: Carry out a reset with TECH 2. The new Software Version 12.300 for TECH 2 is available as of TIS CD 43.
| FunctionalGroup: | N - Electrical Equipment |
|---|---|
| Complaint Group: | 13 - No/Poor Function |
| Trouble Code: | None |