Field Remedy: 1500
| Subject: | Anti-theft warning system - Unintentional alarm activation |
|---|
| Models: | Engines: | Option: |
|---|---|---|
| Vectra-C 2002 | All | Anti-theft warning system |
| Complaint: | Unintentional alarm activation. |
|---|---|
| Cause: | Software problem of the following components: Ultrasonic sensor, tilt sensor, ultrasonic module and power sounder. |
| Production: | As of following VIN modified software has been introduced in production: Rüsselsheim: 24.05.02 , W0L0ZCF6921053408 Ellesmere Port: 25.05.02, W0L0ZCF6828091676 |
Remedy:
In case of customer complaint read out alert code with Tech-2. If the power sounder (only Vauxhall) or ultrasonic sensor have triggered the alarm, the ultrasonic sonsor in the BCM has to be reprogramed with Tech-2 (for Vauxhall vehicles the powersounder has to be reprogramed also).
New Tech-2 software 11.400 will be available with TIS 2000 CD 34!
All vehicles which have been reworked according this information, have to be clearly marked by a white dot on the contact switch engine hood.
Labour Times: TC: Hours:
T0 809 00 Reprogram Ultrasonic 90 0,1 ALarm Sensor
The costs for this action will be covered during the normal warranty.
The regular warranty procedure should be used for claiming Set-up-time.
| FunctionalGroup: | N - Electrical Equipment |
|---|---|
| Complaint Group: | 04 - Electrical failures |
| Trouble Code: | None |